high quality UV Sterilizer

Description The UDSBW series UV sterilizer of TOWIN is a split type Medium pressure UV disinfection system for bottled water. It provides an effective safety barrier for source water and UV disinfection of harmful pathogens by using medium-pressure UV sterilizer. It is a chemical-free physical process that produces zero disinfection by-products. Medium pressure UV water system are more cost effective than ozone or membranes. Do you as the manufacturers have the following problems for bottled water?   Filter disinfection no-completely filtering to cause contaminants Ozone disinfection By-product, changing the natural taste, resistance to antibiotics LP UV Disinfection may have photo reactivation or dark repair Technical Parameter Model Inlet/Outlet Reactor Size D*L(mm) Water Flow T/H Total Power 锛圵锛?/strong> TW-UDSBW210-4DN100桅159*915702KW*1 TW-UDSBW220-6DN150桅219*9151302KW*2 TW-UDSBW230-8DN200桅323*9152002KW*3 TW-UDSBW240-8DN200桅323*9152602KW*4 TW-UDSBW310-6DN150桅219*9151203kw*1 TW-UDSBW320-8DN200桅323*9152503kw*2 TW-UDSBW330-10DN250桅323*9153803kw*3 TW-UDSBW340-12DN300桅377*9155003kw*4 TW-UDSBW610-8DN200桅273*9152306kw*1 TW-UDSBW620-12DN300桅323*9155006kw*2 TW-UDSBW630-14DN350桅426*9157506kw*3 TW-UDSBW640-16DN350桅426*91510006kw*4 Features / Benefits 鈥?Lamp: Use imported TOSHIBA high-strength medium voltage lamp 鈥?UV Intensity Sensor: Real-time monitoring of UV lamps: including light intensity, lamp life. 鈥?Quartz tube cleaning system: automatic cleaning system quickly 鈥?Automatic Control System: PLC-based operation and control system (optional) 鈥?Reliability: Ballasts with long life and stable performance 鈥?Safety: Equipment has faults and high temperature alarms, it will automatic shutdown in emergency situations 鈥?Easy to install: Power cabinet and reactor are connecting with standard cable Use conditions Water temperature: 0 掳 C ~ 50 掳 C; Ambient temperature: 5 掳 C ~ 70 掳 C; Relative humidity: less than 93% (at 25 掳C) Voltage: AC380V卤10V, 60Hz Working pressure: 150 psi (10.3 bar), it is forbidden over loading working pressure Sterilization of drinking water: 1cm UV transmittance (T254): 95%~100%; when the original water quality is lower than the national drinking water standard (chromaticity higher than 15 degrees, turbidity higher than 5 degrees, iron content is higher than 0.3 mg / liter), it should be used pre-treatment method to meet the conditions of use of the equipment.high quality UV Sterilizer website:http://www.uv-towin.com/uv-sterilizer/


Посмотреть всю страницу