high quality UV Sterilizer
Description
The UDSBW series UV sterilizer of TOWIN is a split type Medium pressure UV disinfection system for bottled water. It provides an effective safety barrier for source water and UV disinfection of harmful pathogens by using medium-pressure UV sterilizer. It is a chemical-free physical process that produces zero disinfection by-products. Medium pressure UV water system are more cost effective than ozone or membranes.
Do you as the manufacturers have the following problems for bottled water?
Filter disinfection
no-completely filtering to cause contaminants Ozone disinfection
By-product, changing the natural taste, resistance to antibiotics LP UV Disinfection
may have photo reactivation or dark repair
Technical Parameter
Model Inlet/Outlet Reactor Size
D*L(mm) Water Flow
T/H Total Power
锛圵锛?/strong>
TW-UDSBW210-4DN100桅159*915702KW*1
TW-UDSBW220-6DN150桅219*9151302KW*2
TW-UDSBW230-8DN200桅323*9152002KW*3
TW-UDSBW240-8DN200桅323*9152602KW*4
TW-UDSBW310-6DN150桅219*9151203kw*1
TW-UDSBW320-8DN200桅323*9152503kw*2
TW-UDSBW330-10DN250桅323*9153803kw*3
TW-UDSBW340-12DN300桅377*9155003kw*4
TW-UDSBW610-8DN200桅273*9152306kw*1
TW-UDSBW620-12DN300桅323*9155006kw*2
TW-UDSBW630-14DN350桅426*9157506kw*3
TW-UDSBW640-16DN350桅426*91510006kw*4
Features / Benefits
鈥?Lamp: Use imported TOSHIBA high-strength medium voltage lamp
鈥?UV Intensity Sensor: Real-time monitoring of UV lamps: including light intensity, lamp life.
鈥?Quartz tube cleaning system: automatic cleaning system quickly
鈥?Automatic Control System: PLC-based operation and control system (optional)
鈥?Reliability: Ballasts with long life and stable performance
鈥?Safety: Equipment has faults and high temperature alarms, it will automatic shutdown in emergency situations
鈥?Easy to install: Power cabinet and reactor are connecting with standard cable
Use conditions
Water temperature: 0 掳 C ~ 50 掳 C;
Ambient temperature: 5 掳 C ~ 70 掳 C;
Relative humidity: less than 93% (at 25 掳C)
Voltage: AC380V卤10V, 60Hz
Working pressure: 150 psi (10.3 bar), it is forbidden over loading working pressure
Sterilization of drinking water: 1cm UV transmittance (T254): 95%~100%; when the original water quality is lower than the national drinking water standard (chromaticity higher than 15 degrees, turbidity higher than 5 degrees, iron content is higher than 0.3 mg / liter), it should be used pre-treatment method to meet the conditions of use of the equipment.high quality UV Sterilizer
website:http://www.uv-towin.com/uv-sterilizer/